    Multi - mechanism coalescence design and matrix expression of logic action sequences of the over-turn nursing robot Part II: Gesture-state in sets and matrix

    Get PDF
    As is expressed in Part I, Functions and coalescence design of the over-turn nursing robot, the performance and requirements have been put forward with systematic design of several mechanisms. Here, in order to control and function well the over-turn nursing robot, the three-dimensional and five-dimensional Euclidean space with the real number were adopted in terms of sets for gesture of the bedridden person and the corresponding state of the robot, respectively. The matrix method was employed to define and describe the gestures-robot performance and its transition path. The gesture-state sequence matrix not only accurately and clearly expressed the gesture series, state sequence and their corresponding relations, but also laid a theoretical and technical foundation for the path planning from the current gesture to the target one. The control and operation of 7 states and 5 gestures were done to realize the automation and intelligent over-turning safely, comfortably and conveniently

    Multi - mechanism coalescence design and matrix expression of logic action sequences of the over-turn nursing robot Part I: Functions and coalescence design

    Get PDF
    In order to effectively solve the problem in over-turn of a bedridden person with the assistance of external force, a double bed face- three embedded leave over-turn nursing robot with the flexible compensation was put forward, with the abstraction of the bedridden person as an organism. This robot, on the basis of concept gesture of the person in bed and the state of the robot supporting and proving the gesture with the actions and combination of the two bed faces, held the complete function of over-turn nursing with 7 states corresponding to 5 gestures of the bedridden person obeying the fundamental requirements of safety, rapidity, and comport. The design method of "PS-MM-KD" was proposed for multi-mechanism coalescent system with related specific tasks induced from the original problems with Systems Engineering. Mechanics and Mechanisms, then applied in the concrete sub-system design followed by analysis and verification of both the scheme and the sub-systems in the design, using the Kinematics and Dynamics, implementing the gears, chain wheel, slewing mechanism, screw nut and mortise and tenon joint type clutch mechanism design successfully. Based on those above, a "two-bed face/three-leaf embedded flexible compensation nursing robot" was designed adopting to all ages, people of various kinds of body geometry. PLC, sensor and logic algorithm were used to carry out the control and operation of 7 state-5 posture sequences for realization of the automation and intelligent over-turning in safety, comfort, and convenience
    corecore